+ | For an Off-Grid system. when the batteries are full and we still have AC coupled PV power available, that power is lost. We could use that power and send it to a boiler or something similar. For this we are using a device from my-PV called AC-Thor. | ||
+ | |||
+ | The schematic for this kind of system looks like this (the meter from my-PV is not needed in this setup): | ||
+ | |||
+ | {{:: | ||
+ | |||
+ | First setup: | ||
+ | |||
+ | AC-Thor device must be connected on the AC output of the Multi/ | ||
+ | |||
+ | |||
+ | Using the device touch screen, select Information menu and go to the third screen to find the current IP address. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | Open a browser, put that IP address into the address field and press enter | ||
+ | |||
+ | The webpage should look like this: | ||
+ | |||
+ | {{:: | ||
+ | |||
+ | Please check the firmware version on AC-Thor device, must be at least a0010006. | ||
+ | Go to setting and select the “Mode”. For ESS select ”Hot water 3KW”, for off-grid systems, select | ||
+ | |||
+ | {{:: | ||
+ | |||
+ | Go to Frequency-Modus and define Frequency start value 50.1Hz and the Frequency end value 51Hz. | ||
+ | |||
+ | {{:: | ||
+ | |||
+ | On the Multiplus or Quattro, using Ve.config, add the PV Inverter support Assistant. | ||
+ | |||
+ | -> The correct working of the frequency shift in the PV Inverter assistant needs to physically have a PV inverter installed on ACout which can feed into the Victron system. | ||
- | For an Off-Grid system. when the batteries are full and we still have PV power available, that power is lost. We could use that power and send it to a boiler or something similar. For this we are using a device from My PV called AC-Thor. | ||
- | The schematic for this kind of system looks like this: |
actor_offgrid.1558696356.txt.gz · Last modified: 2019-05-24 13:12 by lucian