Both sides previous revisionPrevious revision | Next revisionBoth sides next revision |
battery_compatibility:byd_b-box [2021-11-25 00:05] – guystewart | battery_compatibility:byd_b-box [2021-12-14 06:53] – [2. Minimum Battery Sizing] guystewart |
---|
|Phases| Single Phase| Three Phase| Single Phase| Three Phase| | |Phases| Single Phase| Three Phase| Single Phase| Three Phase| |
| Inverter/Charger | On-Grid | On-Grid | Off-grid | Off-grid | | | Inverter/Charger | On-Grid | On-Grid | Off-grid | Off-grid | |
| Multiplus & Multiplus II & MP-II GX 48/3000/35| 1| 1| 1| 3| | | Multiplus 48/500 & 48/800| 1| 1| 1| 1| |
| Multiplus & Multiplus II & MP-II GX 48/5000/70| 1| 1| 1| 4| | | Multiplus 48/1200 & 48/1600| 1| 2| 1| 2| |
| Inverter RS & Multi RS 48/6000| 1| -| 2| -| | | Multiplus 48/2000| 1| 2| 1| 3| |
| Quattro 48/5000/70-100/100| 1| 1| 1| 4| | | Multiplus & Multiplus II & MP-II GX 48/3000/35| 1| 3| 2| 4| |
| Quattro 48/8000/110-100/100| 1| 2| 2| 5| | | Multiplus & Multiplus II & MP-II GX 48/5000/70| 2| 5| 3| 6| |
| Quattro 48/10000/140- 100/100| 1| 2| 3| 7| | | Inverter RS & Multi RS 48/6000| 2| -| 3| -| |
| Quattro 48/15000/200- 100/100| 1| 3| 4| 10| | | Quattro 48/5000/70-100/100| 2| 5| 3| 6| |
| EasySolar & EasySolar-II 48/3000/35-50 MPPT150/70| 1| 1| 1| 3| | | Quattro 48/8000/110-100/100| 3| 8| 4| 10| |
| EasySolar 48/5000/70-100 MPPT150/100| 1| 1| 1| 4| | | Quattro 48/10000/140- 100/100| 4| 10| 5| 13| |
| | Quattro 48/15000/200- 100/100| 5| 14| 6| 16| |
| | EasySolar & EasySolar-II 48/3000/35-50 MPPT150/70| 1| 3| 2| 4| |
| | EasySolar 48/5000/70-100 MPPT150/100| 2| 5| 2| 6| |
| |
| |
| |
The specification for these minimum battery sizes was obtained from [[http://alpspower.com.au/wp-content/uploads/2018/05/Battery-Box-LV-Res-2.510.0-Mini-configuration-list.pdf|BYD’s 2018 minimum specification guide.]] There is an [[http://alpspower.com.au/wp-content/uploads/2017/10/B-BOX-LV-Pro-13.8-Minimum-configuration-list.pdf|additional guide here]] for the 12.8 and 13.8 models, and [[https://secureservercdn.net/198.71.233.41/x4m.ee6.myftpupload.com/wp-content/uploads/2020/03/BYD-Battery-Box-Premium-LVL-Minimum-Configuration-List-V1.0.pdf|here for the Premium LVL 15.4 model.]] | The specification for these minimum battery sizes was obtained from [[http://alpspower.com.au/wp-content/uploads/2018/05/Battery-Box-LV-Res-2.510.0-Mini-configuration-list.pdf|BYD’s 2018 minimum specification guide.]] There is an [[http://alpspower.com.au/wp-content/uploads/2017/10/B-BOX-LV-Pro-13.8-Minimum-configuration-list.pdf|additional guide here]] for the 12.8 and 13.8 models, and [[https://secureservercdn.net/198.71.233.41/x4m.ee6.myftpupload.com/wp-content/uploads/2020/03/BYD-Battery-Box-Premium-LVL-Minimum-Configuration-List-V1.0.pdf|here for the Premium LVL 15.4 model.]] |
| |
| |
===== 3. CAN-Bus wiring between the battery and GX Device ===== | ===== 3. CAN-Bus wiring between the battery and GX Device ===== |