ccgx:pump_start_stop
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
drafts:pump_start_stop [2016-07-20 14:07] – [Configuration] jperez | ccgx:pump_start_stop [2019-01-22 10:42] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 4: | Line 4: | ||
===== Introduction ===== | ===== Introduction ===== | ||
- | The CCGX internal | + | The CCGX has a relay - switch - which can automatically |
- | With this functionality you can open or close the relay based on a tank level. | + | ==== Boat & Motorhome overview ==== |
- | ==== Mobile/ | + | An additional Overview page is available which shows at-a-glance status information from all tanks connected to the CCGX. To enable the tank overview |
- | On this overview you can easily see all the attached tank sensors levels and control a pump. It is also posible to change Multi/ | + | It is also posible to change Multi/ |
{{: | {{: | ||
+ | |||
==== Enable pump start/stop ==== | ==== Enable pump start/stop ==== | ||
- | To enable the pump start/stop functionality go to Settings-> | + | To enable the pump start/stop functionality go to Settings ->Relay; and set the function to "Tank pump" |
{{: | {{: | ||
- | |||
==== Configuration ==== | ==== Configuration ==== | ||
- | Pump start/ | + | Once enabled the tank pump configuration page will be found at: Main Menu ->Settings ->Tank pump. |
{{: | {{: | ||
- | {{: | ||
- | {{: | ||
- | **Mode:** | + | ==== Mode ==== |
* **Auto:** Start and stop the pump based on level settings | * **Auto:** Start and stop the pump based on level settings | ||
* **On:** Pump always on | * **On:** Pump always on | ||
* **Off:** Pump always off | * **Off:** Pump always off | ||
- | **Tank sensor**: | + | |
+ | {{: | ||
+ | |||
+ | ==== Tank sensor | ||
Select which sensor will be monitored to start/stop the pump when the " | Select which sensor will be monitored to start/stop the pump when the " | ||
+ | |||
+ | {{: | ||
+ | |||
+ | |||
+ | ==== Pump auto-start levels ==== | ||
+ | |||
**Start level:** When the tank level reaches this value the pump will be started. | **Start level:** When the tank level reaches this value the pump will be started. |