mppt-error-codes [2024-02-12 05:48] – [Err 54 - Inverter output voltage] guy_stewart | mppt-error-codes [2025-03-17 16:46] (current) – [Err 76 - Insufficient inverters] rvanzundert | ||
---|---|---|---|
Line 241: | Line 241: | ||
Make sure all settings are the same and update firmware on all chargers to the latest version. | Make sure all settings are the same and update firmware on all chargers to the latest version. | ||
+ | |||
+ | This error also appears if MPPTs are connected to a GX device while configured for a VE.Smart network. Disable the VE.Smart networking features and use DVCC on the GX instead. | ||
+ | |||
+ | [[https:// | ||
+ | |||
Line 315: | Line 320: | ||
The inverters remain operational, | The inverters remain operational, | ||
+ | |||
+ | ==== Err 75 - Network misconfigured ==== | ||
+ | Applies to Multi RS models. Firmware versions 1.19 and higher. | ||
+ | |||
+ | Three phase operation is not yet certified in combination with the selected grid code. | ||
+ | |||
+ | The inverters remain operational, | ||
+ | |||
+ | ==== Err 76 - Network incomplete ==== | ||
+ | Applies to Inverter RS and Multi RS models. | ||
+ | |||
+ | The inverters shut down because there are insufficient units to operate a networked setup. Check if all required units are powered on and that the CAN interface cables are connected properly. | ||
+ | All units remain off until the installation is fixed, after which the units resume operation. | ||
+ | |||
+ | Related configuration settings in VictronConnect are " | ||
==== Err 80, Err 81, Err 82, Err 83, Err 84, Err 85, Err 86 and Err 87 - PV Input shutdown ==== | ==== Err 80, Err 81, Err 82, Err 83, Err 84, Err 85, Err 86 and Err 87 - PV Input shutdown ==== |