===== 1. Introduction ===== | ===== 1. Introduction ===== | ||
- | Instances are used in an NMEA2000 | + | ==== 1.1 Purpose of NMEA 2000 instances ==== |
+ | Instances are used in an NMEA 2000 network to identify multiple similar products connected on the same network. | ||
- | As an example, take a system with two battery monitors (one for the main battery bank, and another for the hydraulic-thruster bank) and also a Quattro inverter/ | + | As an example, take a system with two battery monitors (one for the main battery bank, and another for the hydraulic-thruster bank) and also a Quattro inverter/ |
- | For the displays to show these values at the right place, they need to know which voltage belongs to what battery. | ||
- | Before going ahead and change | + | ==== 1.2 Different types of instances |
- | === How can I change the instances? === | + | There various types of instances, and for marine systems are two that matter: the Device instance and the Data instance. The data instance goes by various different names, like Fluid instance, Battery instance and DC instance. |
- | This document describes three options: | + | Details and differences of each type are explained in detail in the [[https:// |
- | - Use [[http:// | + | ==== 1.3 Considerations before changing |
- | - Use [[https:// | + | |
- | - From the [[open_source: | + | |
- | === Device instance, data instances | + | First of all, note that it is only rarely necessary to change either device or data instances |
- | There various types of instances. Please make sure to study [[https:// | + | |
- | In summary, and as per NMEA2000 specification, | + | When it is necessary |
- | === Required hardware === | + | **GX devices, NMEA2000-out feature** |
- | Changing | + | All instances of the transmitted by a GX device |
- | | + | **Other products: Device instance** |
- | | + | |
- | === Related information === | + | The NMEA 2000 device instance, which is the same as the VE.Can device instance, is by default set to 0 on all Victron products. |
- | For more detailed information, see also the FAQ in our [[https:// | + | Some products, such as Lynx Smart BMS, Solar chargers with a VE.Can port and Battery chargers |
- | And the main [[ve.can:nmea-2000: | + | **Battery chargers: Data instances (Battery- and DC instance)** |
- | ===== 2. Changing | + | Whilst it is possible to change the Battery and DC instances on a Skylla-i battery charger, changing those will render it impossible for a GX device to properly read the data. This is because the GX device expects the charger' |
+ | |||
+ | ==== 1.4 Recommend instancing setup for main MFD brands | ||
+ | |||
+ | The only common use case we encounter in testing and support where it is necessary to change instances is with older Raymarine hardware & software: | ||
+ | |||
+ | * Raymarine i70: max number of tank levels is 5; fluid instance 0-4 and type must be fuel. | ||
+ | * Raymarine i70s: max number of tank levels is 5; fluid instance 0-4 and type must be fuel. | ||
+ | * Axiom MFDs: per Lighthouse version 4.1.75, a maximum of 16 tanks can be connected; fluid instance 0-15. | ||
+ | |||
+ | Further details per brand are in these documents: | ||
+ | |||
+ | * [[venus-os: | ||
+ | * [[venus-os: | ||
+ | * [[venus-os: | ||
+ | * [[venus-os: | ||
+ | |||
+ | ==== 1.5 Different methods for setting up instances ==== | ||
+ | |||
+ | As the NMEA2000 protocol prescribes commands to change an instance | ||
+ | |||
+ | Besides the here described methods there are more, for example some MFDs allow changing instances as well. | ||
+ | |||
+ | - GX Device: Device- instances only | ||
+ | - Actisense software + NGT-1 USB: Device- as well as data-instances | ||
+ | - Maretron software + USB adapter: Unknown | ||
+ | - Commandline of a [[venus-os: | ||
+ | |||
+ | Chapter 2, 3, 4, 5 and 6 explain these methods in detail. | ||
+ | |||
+ | ==== 1.6 Further reading on Victron and NMEA 2000 ==== | ||
+ | |||
+ | * [[ve.can: | ||
+ | * [[https:// | ||
+ | * [[https:// | ||
+ | * [[https:// | ||
+ | |||
+ | ===== 2. GX Device: changing device instances ===== | ||
+ | |||
+ | The Settings -> Services -> VE.Can -> Devices menu shows a list of all devices on the N2K / VE.Can network: | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | By clicking the right button, a detailed menu is shown: | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | |||
+ | ===== 3. Actisense: changing device instances | ||
Note: make sure to use a recent Actisense driver. Otherwise the instance might not ‘stick’. | Note: make sure to use a recent Actisense driver. Otherwise the instance might not ‘stick’. | ||
+ | |||
+ | Requires the [[http:// | ||
Changing a device instance: | Changing a device instance: | ||
Line 50: | Line 96: | ||
{{: | {{: | ||
- | ===== 3. Changing a data instance with Actisense ===== | + | ===== 4. Actisense: changing data instances |
- | Changing a data instance: | + | Requires the [[http:// |
+ | |||
+ | Step by step instructions: | ||
- Open Actisense NMEA Reader | - Open Actisense NMEA Reader | ||
- Select data view (tab selection is at the bottom left) | - Select data view (tab selection is at the bottom left) | ||
- | - Right click on the PGN number. Note that this will only work on PGNs that allow changing their data instance: \\ {{: | + | - Right click on the PGN number. Note that this will only work on PGNs that allow changing their data instance |
- | - And change the value: \\ {{: | + | - And change the value (second screenshot below) |
- | Notes for BMVs, Lynx Shunt and the Lynx Ion + Shunt: | + | Notes: |
- | + | * The Battery Instance and the DC instance are the same value within Victron products. Changing one of them, will also change the other one. | |
- | * The Battery Instance and the DC Detailed | + | |
* Since the BMV sends out two voltages, the main voltage and the aux- or starter-voltage, | * Since the BMV sends out two voltages, the main voltage and the aux- or starter-voltage, | ||
+ | * Changing the fluid level instance using Actisense has a bug. Probably due Actisense seeing it as 8 bit number; while in the definition it is a 4 bit number. Work around: using the GX, set the fluid type to Fuel (0), then using Actisense change the fluid instance to the desired value, and then using your GX, set the type back to the desired type. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | {{: | ||
+ | |||
+ | |||
- | ===== 4. Changing Instance Using Maretron N2KAnalyzer ===== | + | ===== 5. Maretron N2KAnalyzer ===== |
Maretron uses a term called " | Maretron uses a term called " | ||
WARNING: At Victron we do not understand what and how the Maretron software works with regards to this. We advise to use another tool, not Maretron, so that you know what you are doing, ie know what instance you are changing. | WARNING: At Victron we do not understand what and how the Maretron software works with regards to this. We advise to use another tool, not Maretron, so that you know what you are doing, ie know what instance you are changing. | ||
+ | So far, we have not been able to use Maretron software to change a data instance. And changing the other instance, the device instance can also be done straight from the Victron GX device its user interface. To change a data instance, for example to fix instance conflicts as reported by the Maretron software, we recommend to use Actisense. Not Maretron. | ||
- | Open N2KAnalyzer and make sure that the " | + | ===== 6. Changing |
- | {{:ve.can:maretronn2kanalyzeruniqueinstancecolumn.jpg?850|}} | + | ==== 6.1 Introduction ==== |
+ | Instead of using Actisense or Maretron software, it is also possible to change the VE.Can aka N2K Device instance from the GX Device shell. To get root access, follow these instructions: | ||
- | Within | + | Once logged into the shell, follow below instructions. More back ground information of the used commands such as dbus and dbus-spy is found by reading about root access document. |
- | {{:ve.can:maretronn2kanalyzeranalyzeinstancing.jpg? | + | ==== 6.2 Warning: better use an Actisense! ==== |
- | ===== 5. Changing | + | Note that the methods explained in this Chapter 6 are usually not recommended. Use an Actisense instead, see chapters 3 and 4 instead. |
- | Instead | + | |
+ | ==== 6.3 New method - changing a Device instance | ||
+ | |||
+ | All devices available on the canbus are enumerated under the com.victronenergy.vecan service. And for all devices that support | ||
+ | |||
+ | < | ||
+ | # dbus -y com.victronenergy.vecan.can0 / GetValue | ||
+ | value = { | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | ' | ||
+ | [and so forth] | ||
+ | </ | ||
+ | |||
+ | To change them, do a SetValue call to the DeviceInstace path like below. Or, perhaps easier, use the dbus-spy tool. | ||
+ | |||
+ | These lines read it, then changes it to 1, then reads it again: | ||
+ | < | ||
+ | root@ccgx: | ||
+ | value = 0 | ||
+ | root@ccgx: | ||
+ | retval = 0 | ||
+ | root@ccgx: | ||
+ | value = 1 | ||
+ | |||
+ | [note that numbers, like can0, and 00002CC005EB can ofcourse be different on your system]. | ||
+ | </ | ||
+ | |||
+ | ==== 6.4 New method - changing Data instance | ||
+ | |||
+ | This applies only the NMEA2000-out feature. See links on top of page for what the NMEA2000 out feature is. | ||
+ | |||
+ | The data instances used for the NMEA2000 out feature are stored in local settings. Here is a snippet of the lines, taken by using the dbus-spy tool that also allows changing entries: | ||
+ | |||
+ | The Data instances are the " | ||
+ | < | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | Settings/ | ||
+ | </ | ||
+ | |||
+ | ==== 6.5 Old method ==== | ||
+ | |||
+ | (Only allows changing Device instances - not data instances as used in the NMEA2000-out function) | ||
- | Once logged into the shell, follow below instructions. Note that the example shown changes the device instance of a Skylla-i. The device instance of a VE.Can connected MultiPlus or Quattro can be changed as well. It will show as '' | ||
Step 1. List the devices: | Step 1. List the devices: | ||
Line 107: | Line 244: | ||
Device instance changed successful! | Device instance changed successful! | ||
- | |||