ve.can:changing_nmea2000_instances
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revision | |||
ve.can:changing_nmea2000_instances [2025-02-06 17:35] – mvader | ve.can:changing_nmea2000_instances [2025-02-06 22:04] (current) – [1.3 Considerations before changing instances] mvader | ||
---|---|---|---|
Line 17: | Line 17: | ||
==== 1.3 Considerations before changing instances ==== | ==== 1.3 Considerations before changing instances ==== | ||
- | It is only rarely necessary to change either device or data instances like the Fluid-, Battery- and DC-instance. | + | First of all, note that it is only rarely necessary to change either device or data instances like the Fluid-, Battery- and DC-instance. |
- | **Changing | + | When it is necessary or required to change |
- | All instances can be set to any value, there is no related functionality, | + | **GX devices, NMEA2000-out feature** |
- | **Device instance** | + | All instances of the transmitted by a GX device can be set to any value, there is no related functionality. Includes device instances, and data instances. |
+ | |||
+ | **Other products: | ||
The NMEA 2000 device instance, which is the same as the VE.Can device instance, is by default set to 0 on all Victron products. | The NMEA 2000 device instance, which is the same as the VE.Can device instance, is by default set to 0 on all Victron products. | ||
Line 29: | Line 31: | ||
Some products, such as Lynx Smart BMS, Solar chargers with a VE.Can port and Battery chargers with a VE.Can port, have functionality that relates to the device instance. Therefore make sure to read the manual of that product before changing the device instance. | Some products, such as Lynx Smart BMS, Solar chargers with a VE.Can port and Battery chargers with a VE.Can port, have functionality that relates to the device instance. Therefore make sure to read the manual of that product before changing the device instance. | ||
- | **Data instances | + | **Battery chargers: |
Whilst it is possible to change the Battery and DC instances on a Skylla-i battery charger, changing those will render it impossible for a GX device to properly read the data. This is because the GX device expects the charger' | Whilst it is possible to change the Battery and DC instances on a Skylla-i battery charger, changing those will render it impossible for a GX device to properly read the data. This is because the GX device expects the charger' |
ve.can/changing_nmea2000_instances.1738859731.txt.gz · Last modified: 2025-02-06 17:35 by mvader