ve.can:nmea-2000:start
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
ve.can:nmea-2000:start [2025-01-22 00:33] – [1.4 NMEA2000-out feature] mvader | ve.can:nmea-2000:start [2025-02-06 21:54] (current) – [1.2 MFD Integration] mvader | ||
---|---|---|---|
Line 8: | Line 8: | ||
* **MFD (Chart Plotter) Monitoring**: | * **MFD (Chart Plotter) Monitoring**: | ||
- | * **Tank Level Monitoring**: | + | * **Tank Level Monitoring**: |
- | * **NMEA2000-out feature**: Share tank data, as well as other data such as Battery, DC & AC system data from GX devices to the NMEA2000 | + | * **NMEA2000-out feature**: Share tank data, as well as other data such as Battery, DC & AC system data from GX devices to the NMEA 2000 network. |
- | * **GPS Integration**: | + | * **GPS Integration**: |
- | * **Signal K Powered Features**: Includes wireless AIS, anchor alarms, and automatic trip logging. | + | * **Advanced features powered by Signal K**: Includes wireless AIS, anchor alarms, and automatic trip logging. |
This document serves as a high-level overview with links to relevant manuals for detailed setup instructions. | This document serves as a high-level overview with links to relevant manuals for detailed setup instructions. | ||
Line 19: | Line 19: | ||
Integration with MFDs depends on customer requirements and equipment used. A GX device (e.g., Cerbo GX or Ekrano GX) is typically involved, with two main options: | Integration with MFDs depends on customer requirements and equipment used. A GX device (e.g., Cerbo GX or Ekrano GX) is typically involved, with two main options: | ||
- | - **NMEA2000 | + | - **NMEA 2000 Integration**: |
- **HTML5 App Integration**: | - **HTML5 App Integration**: | ||
**Comparison of Options:** | **Comparison of Options:** | ||
- | - **NMEA2000**: Offers customizable data pages on the MFD but requires more configuration. | + | - **NMEA 2000**: Offers customizable data pages on the MFD but requires more configuration. |
- **HTML5 App**: Plug-and-play with an auto-configured system overview but less customizable. | - **HTML5 App**: Plug-and-play with an auto-configured system overview but less customizable. | ||
**Illustration**: | **Illustration**: | ||
- | {{ : | + | {{ : |
- | * Right bar: NMEA2000 | + | * Right bar: NMEA 2000 data. |
* Bottom: HTML5 App integration. | * Bottom: HTML5 App integration. | ||
Line 43: | Line 43: | ||
==== 1.3 Tank monitoring ==== | ==== 1.3 Tank monitoring ==== | ||
- | The Victron GX devices offer a user-friendly **Tank Level Page** to centralize and visualize data, as well as integration with MFDs and the NMEA2000 | + | The Victron GX devices offer a user-friendly **Tank Level Page** to centralize and visualize data, as well as integration with MFDs and the NMEA 2000 network. |
**Key Features:** | **Key Features:** | ||
* Monitor tank levels on the GX device and VRM Portal. | * Monitor tank levels on the GX device and VRM Portal. | ||
- | * Access | + | * Access |
* Customize tank naming, shapes, and damping for accurate readings. | * Customize tank naming, shapes, and damping for accurate readings. | ||
* Expand capabilities with the [[https:// | * Expand capabilities with the [[https:// | ||
Line 58: | Line 58: | ||
{{ : | {{ : | ||
+ | |||
+ | ** Video that demonstrates the tank page on the GX** | ||
+ | |||
+ | | ||
+ | |||
=== Further details === | === Further details === | ||
* **Resistive tank level inputs built-in to the Cerbo GX and Ekrano GX:** See [[https:// | * **Resistive tank level inputs built-in to the Cerbo GX and Ekrano GX:** See [[https:// | ||
- | * **Reading data from NMEA2000 | + | * **Reading data from NMEA 2000 Tank senders into the GX Device and VRM Portal:** The GX device can read tank level data from compatible sensors on the NMEA 2000 network. This information is then displayed on the GX interface, including the dedicated tank level page, and synced with the VRM Portal. For compatibility details, see [[https:// |
- | * **Transmitting GX tank levels to the NMEA2000 | + | * **Transmitting GX tank levels to the NMEA 2000 network:** For vessels with advanced monitoring setups, the GX device can also send tank data back to the NMEA 2000 network, enabling MFDs and other connected devices to access and display the information. For further information, |
==== 1.4 NMEA2000-out feature ==== | ==== 1.4 NMEA2000-out feature ==== | ||
Line 71: | Line 76: | ||
- | ==== 1.5 Signal K features | + | ==== 1.5 Advanced features powered by Signal K ==== |
Signal K unlocks powerful features: | Signal K unlocks powerful features: | ||
- | * **Wireless AIS & Navigation Data**: Share NMEA2000 | + | * **Wireless AIS & Navigation Data**: Share NMEA 2000 data via WiFi for apps like Navionics. |
* **Anchor Alarm**: Reliable and easy-to-use alarm. | * **Anchor Alarm**: Reliable and easy-to-use alarm. | ||
* **Automatic Logbook**: Track journeys effortlessly. | * **Automatic Logbook**: Track journeys effortlessly. | ||
Line 84: | Line 89: | ||
==== 1.5 Modbus-TCP, mostly for SCADA systems ==== | ==== 1.5 Modbus-TCP, mostly for SCADA systems ==== | ||
- | Ideal for larger vessels, the GX built-in Modbus-TCP server enables SCADA system integration. For more details, see the [[Modbus-TCP FAQ]]. | + | Ideal for larger vessels, the GX built-in Modbus-TCP server enables SCADA system integration. For more details, see the [[https:// |
===== 2. Integration details by Victron product ===== | ===== 2. Integration details by Victron product ===== | ||
Line 94: | Line 99: | ||
==== 2.2 Other products featuring a VE.Can port ==== | ==== 2.2 Other products featuring a VE.Can port ==== | ||
- | All Victron products that feature a VE.Can port can be directly connected to the NMEA 2000 network, using the [[https:// | + | All Victron products that feature a VE.Can port can be directly connected to the NMEA 2000 network, using the [[https:// |
* Skylla-i 24V Battery Chargers | * Skylla-i 24V Battery Chargers | ||
Line 101: | Line 106: | ||
* Lynx Smart BMS | * Lynx Smart BMS | ||
* SmartSolar MPPT Solar Chargers with VE.Can communications port | * SmartSolar MPPT Solar Chargers with VE.Can communications port | ||
+ | * Multi RS | ||
+ | * Inverter RS | ||
{{ : | {{ : | ||
Line 111: | Line 118: | ||
Note that the use of both those interfaces is deprecated. Use a GX device instead. | Note that the use of both those interfaces is deprecated. Use a GX device instead. | ||
- | ===== 3. NMEA2000 | + | ===== 3. NMEA 2000 Details ===== |
==== 3.1 PGN Lists ==== | ==== 3.1 PGN Lists ==== | ||
Line 117: | Line 124: | ||
Refer to our [[https:// | Refer to our [[https:// | ||
- | ==== 3.2 NMEA 2000 instancing | + | ==== 3.2 NMEA 2000 instances |
+ | |||
+ | Instances are used in an NMEA 2000 network to identify multiple similar products connected to the same network. | ||
- | NMEA 2000 Instances are used to identify multiple similar products connected on the same network. | + | As an example, take a system with two battery monitors (one for the main battery bank, and another for the hydraulic-thruster bank) and also a Quattro inverter/ |
- | There are several | + | There are various |
- | More information about instances | + | NMEA 2000 defines three different |
- | === What settings need to be made? For example | + | * Data instances |
+ | * Device instance | ||
+ | * System instance | ||
- | That is a commonly asked question. The answer depends on the used brand of MFD: | + | === When is manual configuration |
- | For **Garmin, Furuno, Maretron and Navico (B&G, Lowrance, Simrad) systems**: | + | * For **Garmin, Furuno, Maretron and Navico (B&G, Lowrance, Simrad) systems**: |
+ | * For **Raymarine**, | ||
- | For **Raymarine**, | + | === Further reading on NMEA 2000 instances |
+ | * [[https:// | ||
+ | * [[ve.can: | ||
==== 3.3 Terminators and network layout ==== | ==== 3.3 Terminators and network layout ==== | ||
- | A N2K CAN-bus network needs to be laid out as in a backbone configuration, | + | A NMEA 2000 CAN-bus network needs to be laid out as in a backbone configuration, |
* Use the NMEA 2000 cable as the backbone. | * Use the NMEA 2000 cable as the backbone. | ||
Line 143: | Line 157: | ||
Or: | Or: | ||
- | * Have the N2K network on one side, with one terminator. On the other end, change to the Victron network, with also one (Victron) terminator at the end. | + | * Have the NMEA 2000 network on one side, with one terminator. On the other end, change to the Victron network, with also one (Victron) terminator at the end. |
- | The first option is more aligned with the official | + | The first option is more aligned with the official |
==== 3.4 DC Voltage compatibility ==== | ==== 3.4 DC Voltage compatibility ==== | ||
Line 162: | Line 176: | ||
==== 3.5 Galvanic isolation ==== | ==== 3.5 Galvanic isolation ==== | ||
- | When connecting a GX to an NMEA2000 | + | When connecting a GX to an NMEA 2000 network, it is recommend to do so using a galvanically isolated CAN-Bus port. |
This is especially the case when your NMEA backbone and GX are powered from separate power sources or do not share a common ground. These are the two most popular models that feature such galvanically isolated port: | This is especially the case when your NMEA backbone and GX are powered from separate power sources or do not share a common ground. These are the two most popular models that feature such galvanically isolated port: | ||
Line 177: | Line 191: | ||
* [[https:// | * [[https:// | ||
* [[https:// | * [[https:// | ||
- | * [[https:// | + | * [[https:// |
- | ===== 4 Maretron ===== | + | ===== 4. Maretron ===== |
- | All data sent out by Victron devices on the N2K network can be picked up by the Maretron MFDs & software. See the [[http:// | + | All data sent out by Victron devices on the NMEA 2000 network can be picked up by the Maretron MFDs & software. See the [[http:// |
===== 5. FAQ ===== | ===== 5. FAQ ===== | ||
- | === Q1: Can or must both Ethernet and and N2K connection be made between Victron GX and MFD? === | + | === Q1: Can or must both Ethernet and and NMEA 2000 connection be made between Victron GX and MFD? === |
Both can be made at the same time. | Both can be made at the same time. | ||
Line 192: | Line 206: | ||
Ethernet is needed to get the MFD App, as explained above. | Ethernet is needed to get the MFD App, as explained above. | ||
- | And an N2K connection is needed to get data to show in other fields on the MFD. | + | And an NMEA 2000 connection is needed to get data to show in other fields on the MFD. |
See annotated screenshot above for which is what. | See annotated screenshot above for which is what. | ||
ve.can/nmea-2000/start.1737502415.txt.gz · Last modified: 2025-01-22 00:33 by mvader