venus-os:remote_ve.bus_firmware_updates
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
venus-os:remote_ve.bus_firmware_updates [2023-06-23 09:33] – jpasop | venus-os:remote_ve.bus_firmware_updates [2024-11-15 10:37] (current) – [1.2 Limitations and requirements] guy_stewart | ||
---|---|---|---|
Line 22: | Line 22: | ||
* In case of another GX Device, ie. a Cerbo, Venus GX, or otherwise, there is no minimum hardware version - they all meet the requirements. | * In case of another GX Device, ie. a Cerbo, Venus GX, or otherwise, there is no minimum hardware version - they all meet the requirements. | ||
* Venus OS firmware must be 2.65 or later. | * Venus OS firmware must be 2.65 or later. | ||
- | * Two Way Communication must be enabled in the VRM menu of the GX device | + | * The '' |
===== 2. Preparations ===== | ===== 2. Preparations ===== | ||
Line 37: | Line 37: | ||
==== 2.2 Disconnect VE.Bus BMS and/or Digital Multi Control ==== | ==== 2.2 Disconnect VE.Bus BMS and/or Digital Multi Control ==== | ||
- | It is not possible to update a VE.Bus inverter, or inverter/ | + | It is not possible to update a VE.Bus inverter, or inverter/ |
+ | This exception does not apply to a MultiPlus or Quattro with VE.Bus BMS V2. In such systems, a remote firmware update of the VE.Bus inverter or inverter/ | ||
Error 734, “Cannot update with DMC or VE.Bus BMS connected” will be shown during the process when attempting to update such system. No settings or firmware is altered at the time, the system will remain operational. | Error 734, “Cannot update with DMC or VE.Bus BMS connected” will be shown during the process when attempting to update such system. No settings or firmware is altered at the time, the system will remain operational. |
venus-os/remote_ve.bus_firmware_updates.1687505631.txt.gz · Last modified: 2023-06-23 09:33 by jpasop