User Tools

Site Tools


victronconnect:beta

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
victronconnect:beta [2024-06-07 16:54] – [v6.07 (Released officially)] jperezvictronconnect:beta [2024-09-24 10:05] (current) – [v6.09.1 (Released officially)] jperez
Line 10: Line 10:
  
 (Currently available betas are on top. See further below for official releases.) (Currently available betas are on top. See further below for official releases.)
 +
 +==== v6.10beta13 ====
 +** 2024-09-11 **
 +
 +__Download links:__
 +
 +  * iOS: Join TestFlight https://testflight.apple.com/join/cvufYMEh 
 +  * [[https://www.dropbox.com/scl/fi/orkimz54x9yqjlmn8qap4/VictronConnect-v6.10beta13-arm64_v8a.apk?rlkey=vcs70vmwmf5viyic6sby4l0c3&dl=1|Android ARM64 ]]*
 +  * [[https://www.dropbox.com/scl/fi/6wtbh7husvp9mqi4gddjs/VictronConnect-v6.10beta13-x86_64.apk?rlkey=72vm1p627u9t1dk8993zib1hd&dl=1|Android x86_64]]*
 +  * [[https://www.dropbox.com/scl/fi/0rmcduskhe7khn9653zl1/VictronConnectInstaller.exe?rlkey=lekzlxmrexljgzg1o6opn72jm&dl=1|Windows 10 and higher]]
 +  * [[https://www.dropbox.com/scl/fi/up3ak71ao72q35goxez4c/VictronConnect.dmg?rlkey=jw97dvv4u8lzmut3gaa6dwyrw&dl=1|macOS 11 (Big Sur) and higher]]
 +  * [[https://www.dropbox.com/scl/fi/1p324wqc6cuyj4rx6drll/VictronConnect-x86_64.AppImage?rlkey=xadz70i7qchmjm5c79ecqh7eb&dl=1|Linux AppImage]]
 +
 +Notes:
 +  * Android: If you can't open the downloaded file from the downloads list try using a file browser.
 +
 +Please report bugs and give feedback to these betas via the Disqus comments below. Please note that comments are not public by default, and first go to a moderation queue.
 +
 +__Changes__
 +
 +  * Add Korean translation
 +
 +Energy Meter:
 +  * Add firmware v1.08:
 +    * Hide L2-L3 line voltage in split phase configuration
 +      * This was introduced in v1.07, which was only in VictronConnect beta.
 +    * Improve VE.Can communication; this fixes the missing custom name
 +
 +Solar Chargers:
 +  * Fix the issue where "Load output configuration" is not available as an RX port mode setting on certain models where it should be.
 +
 +==== v6.10beta12 ====
 +** 2024-09-07 **
 +
 +__Changes__
 +
 +VE.Bus Inverter/Chargers:
 +  * Fix error 122 when updating VE.Bus BMS V2 based systems
 +  * Fix system configuration missing phase selection buttons
 +
 +SmartShunt:
 +  * Add support for new models
 +
 +Lynx Smart BMS: 
 +  * Improve mode button visibility
 +  * Fix maximum starter voltage value for BMV & SmartShunt demos
 +
 +
 +==== v6.10beta11 ====
 +** 2024-08-30 **
 +
 +__Changes__
 +
 +  * Restore the "VictronConnect" name on the splash screens
 +
 +Orion XS:
 +  * Add firmware v1.05 update (mandatory)
 +    * Improve non-volatile memory management by fixing a bug that could cause memory corruption when flashing the history or settings data. This is yet another improvement on top of what was done previously on v1.04.
 +    * Fix operation time count when Orion XS is not charging (Off state)
 +
 +Energy Meter:
 +  * Fix phase configuration setting (issue introduced in beta10)
 +  * Energy counters renaming/rewording
 +
 +EVCS:
 +  * Network settings rewording
 +  * Add new settings
 +
 +GlobalLink:
 +  * Add support for new model
 +
 +MultiHS
 +  * Add ESS Settings (now similar to the InverterRS family)
 +  * Removed the solar data section
 +
 +
 +VE.Bus Inverter/Charger:
 +  * Fix System configuration does not show Phase selection buttons
 +
 +Solar Chargers:
 +  * Improve behaviour when scrolling solar history graphs.
 +
 +==== v6.10beta10 ====
 +** 2024-08-09 **
 +
 +__Changes__
 +
 +Android: Fix firmware and settings files are not added to the library when opening from a file manager while VictronConnect is not already running
 +
 +GX products:
 +  * Better handle local MQTT connection for Venus versions supportin secured profiles
 +
 +Energy Meter:
 +  * Add firmware v1.07:
 +    * Add line-to-line voltages
 +    * Add neutral current
 +    * Add split phase support (L1/L2)
 +    * Add energy registration method
 +      * Users can choose between vector (default), arithmetic and absolute
 +    * Add roles for EV charger, heat pump, water pump and water heater
 +    * Fix missing messages/responses in VE.Can communication
 +    * Fix Ethernet state being invalid in VictronConnect
 +
 +**Below changes are already included in v6.08**
 +
 +Lynx SmartBMS:
 +  * Add firmware v1.11
 +    * Fix bug that prevented the device from automatically switching on after a low cell voltage. The Lynx BMS now switches on again when a charge voltage is detected on the system side. This bug was only in the NG versions.
 +    * Add support for the "Pending" state in parallel mode that indicates on the GX that the BMS is waiting until the battery voltage is within a safe range to connect to the operational battery bank. The voltage displayed indicates the voltage at which it will connect.
 +    * v1.10:
 +      * Support for parallel BMS systems, which adds redundancy to a system. Detect other BMSs & optimize behavior for that case - implemented such that in case of no functional CAN-bus communication between the BMSs everything also works. No user setting is required for parallel support. Use in combination with Venus OS v3.40 or later, since that includes the new feature about combining the data into one total "virtual" bank + use that for DVCC. Paralleling is only possible for models with the same current rating. Combining Smart Lithium BMSs and Lithium-NG BMSs is allowed.
 +      * Add 3 seconds delay to start-up procedure, for all system types, to detect parallel BMSs.
 +      * Peukert adjusted to 1.02 and charge-efficiency to 99.5% for more accurate SoC calculation.
 +
 +VE.Bus Inverter/Chargers:
 +  * VE.Bus firmware update: Fix error 123 when updating MultiPlus-II 48/3000/35-32 (already included in v6.08)
 +  * Add firmware v552 
 +
 +==== v6.10beta9 ====
 +** 2024-08-02 **
 +
 +__Changes__
 +
 +GX products:
 +  * Fix connection to local MQTT via when Venus "Unsecured" profile is selected
 +
 +Orion XS:
 +  * Fix Orion XS page does not open when selecting it on the devices list. This bug also affects the demo product.
 +
 +Energy Meter:
 +  * On remote connections, improve handling when the number of phases is changed.
 +
 +==== v6.10beta8 ====
 +** 2024-08-01 **
 +
 +__Changes__
 +
 +  * Improve the layout of the main settings page
 +  * Various fixes and improvements
 +
 +GX products:
 +  * Fix connection to local MQTT via WebSocket Secure is broken
 +  * Fix live data values of products freeze after 30 seconds when connected via local MQTT
 +
 +Orion XS:
 +  * Add firmware v1.04:
 +    * Bug fixes
 +      * Start displaying warning #67 BMS Connection lost. Previous fw version (v1.03) was not displaying the warning, even though the warning was internally activated. While active, the charger will be kept at "Float" state, with a fix 12V output voltage setpoint.
 +      * Improve non-volatile memory management by fixing a bug that could potentially cause memory corruption when flashing the history or settings data.
 +    * Improvements
 +      * Remove auto equalisation support. On previous FW versions, when equalisation was enabled, the charger would perform equalisation every charge cycle, which is not healthy for the battery. Now only the manual equalisation is supported.
 +      * Allow VE.Smart Networking to be configured over VE.Direct.
 +  * Add error #67
 +  * <del>Fix Orion XS page does not open when selecting it on the devices list. This bug also affects the demo product.</del>
 +
 +
 +Multi RS:
 +  * Rename "Withouth batteries" ESS mode to "PV Inverter"
 +  * Fix live data on remote connections when working as PV iverter
 +  * On remote connections, improve handling when the Multi RS is set or unset to work as a PV inverter.
 +
 +MPPT Solar Chargers:
 +  * Make firmware v1.64 mandatory for the following models
 +    * SmartSolar Charger MPPT 75/10 (A074)
 +    * SmartSolar Charger MPPT 75/15 (A075)
 +    * BlueSolar Charger MPPT 75/10 (A07C)
 +    * BlueSolar Charger MPPT 75/15 (A07D)
 +  * Add firmware v1.65 for SmartSolar 100/30-12V (A07E)
 +    * Extend internal improvements made on v1.64 for all SmartSolar 100/30-12V models.
 +  * Add firmware v3.16:
 +    * Fix bug on synchronize charging over CAN when two or more MPPTs are connected. This could potentially cause the charger to jump absorption every day.
 +
 +Energy Meter:
 +  * On remote connections, improve handling when the meter role is changed.
 +
 +BMV-712 & SmartShunt:
 +  * On remote connections, improve handling when the monitor mode or DC meter type is changed.
 +
 +
 +==== v6.10beta7 ====
 +** 2024-07-13 **
 +
 +__Changes__
 +
 +  * Various fixes and improvemente for QR quick connect
 +  * Show detailed information if a product is shown as an unknown product in the devices list
 +  * Fix an issue where avatar pictures in certain VRM installations are shown rotated 
 +  * Various fixes and improvements
 +
 +Energy Meter:
 +  * Make L1, L2 & L3 instant readout always visible
 +
 +GX products:
 +  * Add support for security profiles (feature not released yet)
 +    * Make possible to change security profile and set a password via Bluetooth
 +    * Support connection to local MQTT via WebSocket Secure
 +  * Do not show the GX in the product info page of attached products
 +
 +MPPT chargers:
 +  * Add support for new models
 +
 +Multi RS:
 +  * Make the "Without batteries" ESS mode only show on beta firmware
 +  * Add extra settings needed for the Without batteries mode
 +  * Improve the overview main widget
 +  * Add phase rotation settings
 +  * Show the AC Input connection status in the overview main widget
 +  * Add "Low SOC" alarm
 +  * Move mode setting to the general settings menu.
 +  * Improbe "On/Off/Inverter only/Charger only" modes description
 +  * Instant readout: Fix AC In & AC Out now working on remote connections when phase is not L1.
 +  * Fixes on NS Log
 +
 +Lynx Smart BMS:
 +  * Fix mode button is sometimes misplaced
 +
 +SmartShunt:
 +  * Add support for new models
 +
 +==== v6.10beta6 ====
 +** 2024-06-28 **
 +
 +__Download links:__
 +
 +  * iOS: Join TestFlight https://testflight.apple.com/join/cvufYMEh 
 +  * [[https://www.dropbox.com/scl/fi/zsa9plkz8n21c9y205m3x/VictronConnect-v6.10beta6-arm64_v8a.apk?rlkey=w9vgs2vuy1q1navo4x4j12o8m&dl=1|Android ARM64 ]]*
 +  * [[https://www.dropbox.com/scl/fi/g9e2ppcu1mvmhtjykjii0/VictronConnect-v6.10beta6-x86_64.apk?rlkey=87vhp8ol4kfrm9ee8hs23t6at&dl=1|Android x86_64]]*
 +  * [[https://www.dropbox.com/s/iscknnw50p4y6y9/VictronConnectInstaller.exe?dl=1|Windows 10 and higher]]
 +  * [[https://www.dropbox.com/s/gdb4qdat0m3a0pj/VictronConnect.dmg?dl=1|macOS 11 (Big Sur) and higher]]
 +  * [[https://www.dropbox.com/s/e87ymp7fxnplo7r/VictronConnect-x86_64.AppImage?dl=1|Linux AppImage]]
 +
 +Notes:
 +  * Android: If you can't open the downloaded file from the downloads list try using a file browser.
 +
 +Please report bugs and give feedback to these betas via the Disqus comments below. Please note that comments are not public by default, and first go to a moderation queue.
 +
 +__Changes__
 +
 +  * Fix app unresponsiveness for VRM users with a large number of installations
 +  * Make settings lock feature more visible; a lock icon is shown in the settings page even when lock is not set.
 +  * Various UI fixes
 +    
 +GX products:
 +  * Enable MQTT on LAN:
 +    * When connected to a GX device on LAN, you can now access attached products to monitor and configure them.
 +    * Enable MQTT on LAN and MQTT (Plain text) on the GX device to activate this feature. These settings are located in the Settings -> Services menu
 +    * Future Venus versions will change how this feature can be enabled
 +    
 +Lynx SmartBMS:
 +  * Add firmware v1.09: (Including changes from v1.08 & v1.07)
 +    * v1.09
 +      * The problem with the 1000A models that a pre-charge error occurred when pre-charging large capacities at 48V has been solved.
 +      * Improved pre-charge performance for all voltages.
 +    * v1.08 
 +      * Initial version for Lynx Smart BMS 500-NG and 1000-NG that supports the Lithium-NG batteries.
 +      * The issue of the BMS waking up from sleep mode when battery is completely discharged has been fixed.
 +      * ATC contact opens during updates. This is to prevent potentially dangerous situations if an overvoltage occurs during an update.
 +      * The issue where the LED and AUX outputs were occasionally turned on for a second in sleep mode has been fixed.
 +    * v1.07
 +      * Support for Lynx Smart BMS 1000A which includes following improvements:
 +        * Improved current measurement for low currents.
 +        * Variable fan speed based on BMS temperature and contactor dissipation.
 +
 +MPPT RS:
 +  * Add isolation resistance value to the demo product
 +
 +Multi RS:
 +  * Make the "Optimize for feed-in" ESS mode available only for the proper grid codes
 +  * Add new grid code related settings
 +  * Fix the issue where feed-in disabled reasons do not update on remote connections.
 +  * Add sustain voltage settings
 +  * Add ESS Ac Power setpoint setting
  
 ==== v6.10beta5 ==== ==== v6.10beta5 ====
Line 142: Line 414:
 Multi RS: Multi RS:
   * Add Grid Code support. (Requires new firmware not available yet)   * Add Grid Code support. (Requires new firmware not available yet)
 +
 +==== v6.09.1 (Released officially) ====
 +** 2024-09-24 **
 +
 +__Download links:__
 +
 +  * iOS: [[https://itunes.apple.com/app/victronconnect/id943840744?mt=8|App Store]] 
 +  * [[https://play.google.com/store/apps/details?id=com.victronenergy.victronconnect|Android]]
 +  * macOS [[https://itunes.apple.com/app/victronconnect/id1084677271?mt=12|11 (macOS Big Sur) and higher|App Store]]
 +  * [[https://www.victronenergy.com/upload/software/VictronConnect-x86_64-v6.09.1.AppImage|Linux AppImage]]
 +  
 +* Android: If you can't open the downloaded file from the downloads list try using a file browser.
 +
 +__Changes__
 +
 +
 +Phoenix Smart Inverters:
 +  * Fix Bluetooth firmware update problem for a recently shipped batch of Phoenix Smart Inverters. Note that this change unfortunately disables the Settings Lock feature. A new update that re-adds Settings Lock for the Phoenix Smart Inverters is expected soon.
 +
 +==== v6.09 (Released officially) ====
 +** 2024-09-10 **
 +
 +__Changes__
 +
 +
 +VE.Bus Inverter/Chargers:
 +  * Fix error 122 when updating VE.Bus BMS V2 based systems
 +  * Fix system configuration missing phase selection buttons
 +
 +SmartShunt:
 +  * Add support for new models
 +
 +Orion XS:
 +  * Add firmware v1.05 update (mandatory)
 +    * Improve non-volatile memory management by fixing a bug that could cause memory corruption when flashing the history or settings data. This is yet another improvement on top of what was done previously on v1.04.
 +    * Fix operation time count when Orion XS is not charging (Off state)
 +
 +Solar Chargers:
 +  * Add firmware v3.16:
 +    * Fix bug on synchronize charging over CAN when two or more MPPTs are connected. In some rare situations this could potentially cause the charger to jump absorption.
 +  * Improve behaviour when scrolling 30 day history bar graph
 +
 +Energy Meter:
 +  * Fix voltage between PE and Neutral is not shown.
 +
 +==== v6.08 (Released officially) ====
 +** 2024-08-07 **
 +
 +__Changes__
 +
 +Orion XS:
 +  * Add firmware v1.04:
 +    * Bug fixes
 +      * Start displaying warning #67 BMS Connection lost. Previous fw version (v1.03) was not displaying the warning, even though the warning was internally activated. While active, the charger will be kept at "Float" state, with a fix 12V output voltage setpoint.
 +      * Improve non-volatile memory management by fixing a bug that could potentially cause memory corruption when flashing the history or settings data.
 +    * Improvements
 +      * Remove auto equalisation support. On previous FW versions, when equalisation was enabled, the charger would perform equalisation every charge cycle, which is not healthy for the battery. Now only the manual equalisation is supported.
 +      * Allow VE.Smart Networking to be configured over VE.Direct.
 +  * Add error #67
 +  
 +MPPT Solar Chargers:
 +  * Make firmware v1.64 mandatory for the following models
 +    * SmartSolar Charger MPPT 75/10 (A074)
 +    * SmartSolar Charger MPPT 75/15 (A075)
 +    * BlueSolar Charger MPPT 75/10 (A07C)
 +    * BlueSolar Charger MPPT 75/15 (A07D)
 +  * Add firmware v1.65 for SmartSolar 100/30-12V (A07E)
 +    * Extend internal improvements made on v1.64 for all SmartSolar 100/30-12V models.
 +
 +VE.Bus Inverter/Chargers:
 +  * VE.Bus firmware update: Fix error 123 when updating MultiPlus-II 48/3000/35-32
 +  * Add firmware v552
 +
 +Lynx SmartBMS:
 +  * Add firmware v1.11
 +    * Fix bug that prevented the device from automatically switching on after a low cell voltage. The Lynx BMS now switches on again when a charge voltage is detected on the system side. This bug was only in the NG versions.
 +    * Add support for the "Pending" state in parallel mode that indicates on the GX that the BMS is waiting until the battery voltage is within a safe range to connect to the operational battery bank. The voltage displayed indicates the voltage at which it will connect.
 +    * v1.10:
 +      * Support for parallel BMS systems, which adds redundancy to a system. Detect other BMSs & optimize behavior for that case - implemented such that in case of no functional CAN-bus communication between the BMSs everything also works. No user setting is required for parallel support. Use in combination with Venus OS v3.40 or later, since that includes the new feature about combining the data into one total "virtual" bank + use that for DVCC. Paralleling is only possible for models with the same current rating. Combining Smart Lithium BMSs and Lithium-NG BMSs is allowed.
 +      * Add 3 seconds delay to start-up procedure, for all system types, to detect parallel BMSs.
 +      * Peukert adjusted to 1.02 and charge-efficiency to 99.5% for more accurate SoC calculation.
 +
 +Phoenix & SUN Inverter:
 +  * Add firmware v1.36
 +    * Add support for settings lock
 +
  
 ==== v6.07 (Released officially) ==== ==== v6.07 (Released officially) ====
Line 190: Line 548:
   * Add settings lock exceptions   * Add settings lock exceptions
  
 +SmartShunt:
 +  * Add support for SmartShunt 300A model
 ==== v6.05 (Released officially) ==== ==== v6.05 (Released officially) ====
 ** 2023-04-25 ** ** 2023-04-25 **
Line 254: Line 614:
  
 ==== v6.00 (Released officially) ==== ==== v6.00 (Released officially) ====
-** 2023-03-13 **+** 2024-03-13 **
  
 __Changes__ __Changes__
victronconnect/beta.1717772071.txt.gz · Last modified: 2024-06-07 16:54 by jperez

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki