Line 11: | Line 11: | ||
(Currently available betas are on top. See further below for official releases.) | (Currently available betas are on top. See further below for official releases.) | ||
- | ==== v6.10beta9 | + | ==== v6.10beta13 |
- | ** 2024-08-02 ** | + | ** 2024-09-11 ** |
__Download links:__ | __Download links:__ | ||
* iOS: Join TestFlight https:// | * iOS: Join TestFlight https:// | ||
- | * [[https:// | + | * [[https:// |
- | * [[https:// | + | * [[https:// |
* [[https:// | * [[https:// | ||
* [[https:// | * [[https:// | ||
Line 27: | Line 27: | ||
Please report bugs and give feedback to these betas via the Disqus comments below. Please note that comments are not public by default, and first go to a moderation queue. | Please report bugs and give feedback to these betas via the Disqus comments below. Please note that comments are not public by default, and first go to a moderation queue. | ||
+ | |||
+ | __Changes__ | ||
+ | |||
+ | * Add Korean translation | ||
+ | |||
+ | Energy Meter: | ||
+ | * Add firmware v1.08: | ||
+ | * Hide L2-L3 line voltage in split phase configuration | ||
+ | * This was introduced in v1.07, which was only in VictronConnect beta. | ||
+ | * Improve VE.Can communication; | ||
+ | |||
+ | Solar Chargers: | ||
+ | * Fix the issue where "Load output configuration" | ||
+ | |||
+ | ==== v6.10beta12 ==== | ||
+ | ** 2024-09-07 ** | ||
+ | |||
+ | __Changes__ | ||
+ | |||
+ | VE.Bus Inverter/ | ||
+ | * Fix error 122 when updating VE.Bus BMS V2 based systems | ||
+ | * Fix system configuration missing phase selection buttons | ||
+ | |||
+ | SmartShunt: | ||
+ | * Add support for new models | ||
+ | |||
+ | Lynx Smart BMS: | ||
+ | * Improve mode button visibility | ||
+ | * Fix maximum starter voltage value for BMV & SmartShunt demos | ||
+ | |||
+ | |||
+ | ==== v6.10beta11 ==== | ||
+ | ** 2024-08-30 ** | ||
+ | |||
+ | __Changes__ | ||
+ | |||
+ | * Restore the " | ||
+ | |||
+ | Orion XS: | ||
+ | * Add firmware v1.05 update (mandatory) | ||
+ | * Improve non-volatile memory management by fixing a bug that could cause memory corruption when flashing the history or settings data. This is yet another improvement on top of what was done previously on v1.04. | ||
+ | * Fix operation time count when Orion XS is not charging (Off state) | ||
+ | |||
+ | Energy Meter: | ||
+ | * Fix phase configuration setting (issue introduced in beta10) | ||
+ | * Energy counters renaming/ | ||
+ | |||
+ | EVCS: | ||
+ | * Network settings rewording | ||
+ | * Add new settings | ||
+ | |||
+ | GlobalLink: | ||
+ | * Add support for new model | ||
+ | |||
+ | MultiHS | ||
+ | * Add ESS Settings (now similar to the InverterRS family) | ||
+ | * Removed the solar data section | ||
+ | |||
+ | |||
+ | VE.Bus Inverter/ | ||
+ | * Fix System configuration does not show Phase selection buttons | ||
+ | |||
+ | Solar Chargers: | ||
+ | * Improve behaviour when scrolling solar history graphs. | ||
+ | |||
+ | ==== v6.10beta10 ==== | ||
+ | ** 2024-08-09 ** | ||
+ | |||
+ | __Changes__ | ||
+ | |||
+ | Android: Fix firmware and settings files are not added to the library when opening from a file manager while VictronConnect is not already running | ||
+ | |||
+ | GX products: | ||
+ | * Better handle local MQTT connection for Venus versions supportin secured profiles | ||
+ | |||
+ | Energy Meter: | ||
+ | * Add firmware v1.07: | ||
+ | * Add line-to-line voltages | ||
+ | * Add neutral current | ||
+ | * Add split phase support (L1/L2) | ||
+ | * Add energy registration method | ||
+ | * Users can choose between vector (default), arithmetic and absolute | ||
+ | * Add roles for EV charger, heat pump, water pump and water heater | ||
+ | * Fix missing messages/ | ||
+ | * Fix Ethernet state being invalid in VictronConnect | ||
+ | |||
+ | **Below changes are already included in v6.08** | ||
+ | |||
+ | Lynx SmartBMS: | ||
+ | * Add firmware v1.11 | ||
+ | * Fix bug that prevented the device from automatically switching on after a low cell voltage. The Lynx BMS now switches on again when a charge voltage is detected on the system side. This bug was only in the NG versions. | ||
+ | * Add support for the " | ||
+ | * v1.10: | ||
+ | * Support for parallel BMS systems, which adds redundancy to a system. Detect other BMSs & optimize behavior for that case - implemented such that in case of no functional CAN-bus communication between the BMSs everything also works. No user setting is required for parallel support. Use in combination with Venus OS v3.40 or later, since that includes the new feature about combining the data into one total " | ||
+ | * Add 3 seconds delay to start-up procedure, for all system types, to detect parallel BMSs. | ||
+ | * Peukert adjusted to 1.02 and charge-efficiency to 99.5% for more accurate SoC calculation. | ||
+ | |||
+ | VE.Bus Inverter/ | ||
+ | * VE.Bus firmware update: Fix error 123 when updating MultiPlus-II 48/ | ||
+ | * Add firmware v552 | ||
+ | |||
+ | ==== v6.10beta9 ==== | ||
+ | ** 2024-08-02 ** | ||
__Changes__ | __Changes__ | ||
Line 311: | Line 414: | ||
Multi RS: | Multi RS: | ||
* Add Grid Code support. (Requires new firmware not available yet) | * Add Grid Code support. (Requires new firmware not available yet) | ||
+ | |||
+ | ==== v6.09.1 (Released officially) ==== | ||
+ | ** 2024-09-24 ** | ||
+ | |||
+ | __Download links:__ | ||
+ | |||
+ | * iOS: [[https:// | ||
+ | * [[https:// | ||
+ | * macOS [[https:// | ||
+ | * [[https:// | ||
+ | | ||
+ | * Android: If you can't open the downloaded file from the downloads list try using a file browser. | ||
+ | |||
+ | __Changes__ | ||
+ | |||
+ | |||
+ | Phoenix Smart Inverters: | ||
+ | * Fix Bluetooth firmware update problem for a recently shipped batch of Phoenix Smart Inverters. Note that this change unfortunately disables the Settings Lock feature. A new update that re-adds Settings Lock for the Phoenix Smart Inverters is expected soon. | ||
+ | |||
+ | ==== v6.09 (Released officially) ==== | ||
+ | ** 2024-09-10 ** | ||
+ | |||
+ | __Changes__ | ||
+ | |||
+ | |||
+ | VE.Bus Inverter/ | ||
+ | * Fix error 122 when updating VE.Bus BMS V2 based systems | ||
+ | * Fix system configuration missing phase selection buttons | ||
+ | |||
+ | SmartShunt: | ||
+ | * Add support for new models | ||
+ | |||
+ | Orion XS: | ||
+ | * Add firmware v1.05 update (mandatory) | ||
+ | * Improve non-volatile memory management by fixing a bug that could cause memory corruption when flashing the history or settings data. This is yet another improvement on top of what was done previously on v1.04. | ||
+ | * Fix operation time count when Orion XS is not charging (Off state) | ||
+ | |||
+ | Solar Chargers: | ||
+ | * Add firmware v3.16: | ||
+ | * Fix bug on synchronize charging over CAN when two or more MPPTs are connected. In some rare situations this could potentially cause the charger to jump absorption. | ||
+ | * Improve behaviour when scrolling 30 day history bar graph | ||
+ | |||
+ | Energy Meter: | ||
+ | * Fix voltage between PE and Neutral is not shown. | ||
+ | |||
+ | ==== v6.08 (Released officially) ==== | ||
+ | ** 2024-08-07 ** | ||
+ | |||
+ | __Changes__ | ||
+ | |||
+ | Orion XS: | ||
+ | * Add firmware v1.04: | ||
+ | * Bug fixes | ||
+ | * Start displaying warning #67 BMS Connection lost. Previous fw version (v1.03) was not displaying the warning, even though the warning was internally activated. While active, the charger will be kept at " | ||
+ | * Improve non-volatile memory management by fixing a bug that could potentially cause memory corruption when flashing the history or settings data. | ||
+ | * Improvements | ||
+ | * Remove auto equalisation support. On previous FW versions, when equalisation was enabled, the charger would perform equalisation every charge cycle, which is not healthy for the battery. Now only the manual equalisation is supported. | ||
+ | * Allow VE.Smart Networking to be configured over VE.Direct. | ||
+ | * Add error #67 | ||
+ | | ||
+ | MPPT Solar Chargers: | ||
+ | * Make firmware v1.64 mandatory for the following models | ||
+ | * SmartSolar Charger MPPT 75/10 (A074) | ||
+ | * SmartSolar Charger MPPT 75/15 (A075) | ||
+ | * BlueSolar Charger MPPT 75/10 (A07C) | ||
+ | * BlueSolar Charger MPPT 75/15 (A07D) | ||
+ | * Add firmware v1.65 for SmartSolar 100/30-12V (A07E) | ||
+ | * Extend internal improvements made on v1.64 for all SmartSolar 100/30-12V models. | ||
+ | |||
+ | VE.Bus Inverter/ | ||
+ | * VE.Bus firmware update: Fix error 123 when updating MultiPlus-II 48/ | ||
+ | * Add firmware v552 | ||
+ | |||
+ | Lynx SmartBMS: | ||
+ | * Add firmware v1.11 | ||
+ | * Fix bug that prevented the device from automatically switching on after a low cell voltage. The Lynx BMS now switches on again when a charge voltage is detected on the system side. This bug was only in the NG versions. | ||
+ | * Add support for the " | ||
+ | * v1.10: | ||
+ | * Support for parallel BMS systems, which adds redundancy to a system. Detect other BMSs & optimize behavior for that case - implemented such that in case of no functional CAN-bus communication between the BMSs everything also works. No user setting is required for parallel support. Use in combination with Venus OS v3.40 or later, since that includes the new feature about combining the data into one total " | ||
+ | * Add 3 seconds delay to start-up procedure, for all system types, to detect parallel BMSs. | ||
+ | * Peukert adjusted to 1.02 and charge-efficiency to 99.5% for more accurate SoC calculation. | ||
+ | |||
+ | Phoenix & SUN Inverter: | ||
+ | * Add firmware v1.36 | ||
+ | * Add support for settings lock | ||
+ | |||
==== v6.07 (Released officially) ==== | ==== v6.07 (Released officially) ==== | ||
Line 359: | Line 548: | ||
* Add settings lock exceptions | * Add settings lock exceptions | ||
+ | SmartShunt: | ||
+ | * Add support for SmartShunt 300A model | ||
==== v6.05 (Released officially) ==== | ==== v6.05 (Released officially) ==== | ||
** 2023-04-25 ** | ** 2023-04-25 ** |
victronconnect/beta.1722596285.txt.gz · Last modified: 2024-08-02 12:58 by jperez