Line 37: | Line 37: | ||
* Low battery alarm | * Low battery alarm | ||
* Overload alarm | * Overload alarm | ||
+ | * AC Input phase rotation (for three phase systems) | ||
=== 2.1.2 BMV, Lynx Shunt VE.Can and other batteries=== | === 2.1.2 BMV, Lynx Shunt VE.Can and other batteries=== | ||
Line 54: | Line 55: | ||
* High charge current alarm | * High charge current alarm | ||
* High discharge current alarm | * High discharge current alarm | ||
- | * Cell Imbalance | + | * Cell imbalance |
- | * Internal | + | * Internal |
=== 2.1.3 Solar charger === | === 2.1.3 Solar charger === | ||
Line 83: | Line 84: | ||
* Digital input | * Digital input | ||
+ | |||
+ | === 2.1.7 Generator start/stop === | ||
+ | |||
+ | * Generator not detected at AC-input. See [[ccgx: | ||
===== 3. User configurable alarms ===== | ===== 3. User configurable alarms ===== | ||
Line 133: | Line 138: | ||
- | ===== DISQUS | + | ===== 6. VRM Error messages |
- | ~~DISQUS~~ | + | |
+ | ==== Data from unauthenticated device has been received ==== | ||
+ | |||
+ | When transmitting data to the VRM Portal, the device sending the data needs to authenticate itself against VRM. It does this using VRM Authentication tokens. | ||
+ | |||
+ | If either one of those tokens does not match the ones stored in the VRM back-end, then the transmitted data is rejected by VRM, and an error message is shown on the VRM portal. The error message looks like this: | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | These are the causes: | ||
+ | |||
+ | - GX device has been reset to factory defaults, using the venus-data.tgz file as instructed in the manuals. For older GX devices, CCGX, Venus GX, Octo GX, and also older batches of Cerbo GX as well as older batches of MP-II GX and ES-II GX, this will lead to this error message on VRM. | ||
+ | - Hacker trying to send false data to VRM. | ||
+ | - GX device storage corruption (data partition). | ||
+ | - RaspberryPi that has a new sdcard or is re-imaged. | ||
+ | |||
+ | For "1. GX device factory reset" as well as for "4. RaspberryPi", | ||
+ | |||
+ | It is thereafter not needed to restart the GX device. | ||
+ | |||
+ | If that does not resolve it, contact your Victron dealer. | ||
vrm_portal/alarms.1548420907.txt.gz · Last modified: 2019-01-25 13:55 by guy_stewart