vrm_portal:remote-veconfigure
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
vrm_portal:remote-veconfigure [2019-08-15 12:19] – replace venus-device with GX device guy_stewart | vrm_portal:remote-veconfigure [2023-05-15 14:18] (current) – mvader | ||
---|---|---|---|
Line 5: | Line 5: | ||
This manual describes how to remotely change settings in our MultiPlusses, | This manual describes how to remotely change settings in our MultiPlusses, | ||
- | This functionality requires a [[venus-os: | + | ===== 2. Requirements and limitations ===== |
+ | |||
+ | This functionality requires a [[venus-os: | ||
Requirements: | Requirements: | ||
- | - Venus OS v2.17 or later | + | - A GX Device running |
- System must connected to internet and communicating to the VRM Portal. | - System must connected to internet and communicating to the VRM Portal. | ||
- Two way communication must be enabled | - Two way communication must be enabled | ||
- The [[venus-os: | - The [[venus-os: | ||
+ | - [[https:// | ||
Details: | Details: | ||
Line 17: | Line 20: | ||
* Remotely changing Assistant configuration is possible. | * Remotely changing Assistant configuration is possible. | ||
* VE.Bus firmware versions 416 and 417 can not be configured remotely | * VE.Bus firmware versions 416 and 417 can not be configured remotely | ||
- | * Remote configuring firmware version 418 or later requires the CCGX or Venus GX to run v2.10 or later | + | * Remote configuring firmware version 418 or later requires the GX device |
- | * To Remote VEConfigure a system connected to the CCGX via a VE.Bus to VE.Can interface, as was done in old Hub-1 systems, this interface cable needs to run firmware version v2.05 or higher. If necessary, first update that interface cable with the [[vrm_portal: | + | * To Remote VEConfigure a system connected to the GX device |
* This (new) way of Remote VEConfigure replaces the previous mechanism, that used VE.Power Setup. See [[ccgx: | * This (new) way of Remote VEConfigure replaces the previous mechanism, that used VE.Power Setup. See [[ccgx: | ||
+ | * The system protects against accidentally sending settings from one system to another. To that purpose, it will compare the serial numbers of the installed inverter/ | ||
+ | * For systems consisting of multiple inverter/ | ||
- | In some cases the VE.Bus system will momentarily switched off when changing the configuration. See step 4 for more details. | + | In some cases the VE.Bus system will momentarily switched off when changing the configuration. |
- | ===== 2. Step by step procedure ===== | + | ===== 3. Step by step procedure ===== |
{{youtube> | {{youtube> | ||
Line 29: | Line 34: | ||
- Check the requirements | - Check the requirements | ||
- Venus OS v2.17 or later | - Venus OS v2.17 or later | ||
- | - Two way communication enabled (see Settings -> Services | + | - Two way communication enabled (see Settings -> VRM Online Portal |
- Two way communication up & running: check on the Device list page on VRM | - Two way communication up & running: check on the Device list page on VRM | ||
- On the VRM Portal, go to Device List, and scroll to the bottom to find the Remote VEConfigure button on the VRM Portal | - On the VRM Portal, go to Device List, and scroll to the bottom to find the Remote VEConfigure button on the VRM Portal | ||
Line 35: | Line 40: | ||
- the system starts with reading all the settings of each inverter/ | - the system starts with reading all the settings of each inverter/ | ||
- once all data has been gathered; its compiled into a file and uploaded to your computer. | - once all data has been gathered; its compiled into a file and uploaded to your computer. | ||
- | - Download the file to your computer | + | - Download/save the .RSVC file to your computers downloads folder - do not 'open in VEConfigure' |
- | - Modify the configuration, save the file using the Close button in VEConfigure on the upport | + | - Modify the configuration |
- | - Upload the file to the system | + | - Save the file using the Close button in VEConfigure on the upper right. |
+ | - Be Aware - You can only upload the .RVSC file when using Remote VEConfigure. If the file is saved via the File, Save As menu, instead of closing VEConfigure and confirming the changes, it will save to a new .VSC file. This file can be opened, adjusted, and used to update locally with an MK3 adapter, but it cannot be uploaded to update a remote unit. You must use the .RVSC file downloaded from the system that you intend to change the settings of, and then upload that same file once changes are made. | ||
+ | - On the VRM Portal, go to Device List, and scroll to the bottom to find the Remote VEConfigure button on the VRM Portal | ||
+ | - Click the button and wait | ||
+ | - Click the Upload | ||
- | ===== 3. System shutdown during reconfiguration ===== | + | ===== 4. System shutdown during reconfiguration ===== |
Many settings can be changed without resulting in a shutdown during the re-configuration. Some settings though, such as a changed Assistants configuration, | Many settings can be changed without resulting in a shutdown during the re-configuration. Some settings though, such as a changed Assistants configuration, | ||
Line 52: | Line 61: | ||
This is not a problem, as the file is first uploaded to the [[venus-os: | This is not a problem, as the file is first uploaded to the [[venus-os: | ||
- |
vrm_portal/remote-veconfigure.1565864372.txt.gz · Last modified: 2019-08-15 12:19 by guy_stewart