ve.can:pgn_details
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
ve.can:pgn_details [2015-04-29 11:00] – [VE.Direct to VE.Can\NMEA 2000 interface] mbosma | ve.can:pgn_details [2019-01-22 10:43] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== | + | ====== |
- | This page is created to inform you on the details of NMEA 2000 PGNs that are transmitted by Victron CAN enabled products. | + | |
- | ===== Switch Bank Control - PGN 127502 (0x1F20E) (deprecated) | + | This document is an add-on to our Datacommunication whitepaper. That whitepaper contains a list of PGNs transmitted by each product type. This document defines the bit definitions of the switch banks. |
+ | |||
+ | Download the main document, the Datacommunication whitepaper, from the [[https:// | ||
+ | |||
+ | === Proprietary messages: VREGs === | ||
+ | Note that besides the standard NMEA2000 PGNs, Victron devices also transmit proprietary messages, called VREGs. VREGs are used for all parameters cannot be sent with standard NMEA 2000 PGNs. The VREG PGN number is 61184 (0xEF00), and it is sent to the broadcast address 61439 (0xEFFF). | ||
+ | |||
+ | See the document “VE.Can registers - public.docx” for detailed VREG information and examples. It is available for download on the [[https:// | ||
+ | |||
+ | === More CAN-bus and NMEA2000 related documentation === | ||
+ | * [[ve.can: | ||
+ | * [[ve.can: | ||
+ | |||
+ | ===== PGN List ===== | ||
+ | ==== Switch Bank Control - PGN 127502 (0x1F20E) (deprecated) ==== | ||
This message is no longer transmitted and has been replaced by PGN 127501.\\ | This message is no longer transmitted and has been replaced by PGN 127501.\\ | ||
This applies to products with versions as specified in the table below or newer. | This applies to products with versions as specified in the table below or newer. | ||
- | ^ Product | + | ^ Product |
- | | BlueSolar MPPT 150/70 & 150/85 | v2.00 | | + | | BlueSolar MPPT 150/70 & 150/ |
- | | Lynx Shunt VE.Can | + | | Lynx Shunt VE.Can |
- | | Skylla-i | + | | Skylla-i |
- | | VE.Direct to VE.Can\NMEA 2000 | v1.06 | | + | | VE.Direct to VE.Can\NMEA 2000 interface |
- | | VE.Bus to VE.Can\NMEA 2000 | + | | VE.Bus to VE.Can\NMEA 2000 interface |
===== Binary Status Report - PGN 127501 (0x1F20D) ===== | ===== Binary Status Report - PGN 127501 (0x1F20D) ===== | ||
Line 22: | Line 35: | ||
| Status 3 - Low voltage | | Status 3 - Low voltage | ||
| Status 4 - High voltage | | Status 4 - High voltage | ||
- | | Status 5 - Solar activity | + | | Status 5 - Solar activity* |
- | | Status 6 ... 28 | Not used, reports "No Action" | | + | | Status 6 ... 28 | Not used, reports |
+ | * Since v2.01 | ||
When the Alarm status bit is set to " | When the Alarm status bit is set to " | ||
==== Lynx Shunt VE.Can ==== | ==== Lynx Shunt VE.Can ==== | ||
Line 49: | Line 64: | ||
| Status 3 - Low voltage | | Status 3 - Low voltage | ||
| Status 4 - High voltage | | Status 4 - High voltage | ||
- | | Status 5 ... 28 | Not used, reports "No Action" | | + | | Status 5 ... 28 | Not used, reports |
When the Alarm status bit is set to “On”, the alarm reason can be queried using Victron propietary register 0xEDDA (Charger error code). | When the Alarm status bit is set to “On”, the alarm reason can be queried using Victron propietary register 0xEDDA (Charger error code). | ||
+ | |||
==== VE.Direct to VE.Can\NMEA 2000 interface ==== | ==== VE.Direct to VE.Can\NMEA 2000 interface ==== | ||
- | Alarm and relay tresholds need to be configured on the BMV itself. | + | See the manual |
- | ^ Signal | + | |
- | | Bank Instance | + | ==== VE.Bus to VE.Can\NMEA 2000 interface ==== |
- | | Status 1 - Relay | " | + | See the manual |
- | | Status 2 - Alarm | " | + | |
- | | Status 3 – Low voltage* | + | |
- | | Status 4 – High voltage* | + | |
- | | Status 5 – Low SOC* | “On” – The Battery state of charge is too low | | + | |
- | | Status 6 – Low voltage 2* | “On” – Starter Battery voltage is too low | | + | |
- | | Status 7 – High voltage 2* | “On” – Starter Battery voltage is too high | | + | |
- | | Status 8 … 28 | Not used, report as “No Action” | | + | |
- | * BMV version 2.08 and higher | + | |
ve.can/pgn_details.1430298045.txt.gz · Last modified: 2015-04-29 11:00 by mbosma