System with multiple chargers
Refer to the wiring schematic below to connect multiple Blue Smart IP22 Chargers in parallel to a single battery / battery bank, with an optional SmartShunt or BMV battery monitor in the system:

Key | Description |
---|---|
A | AC power supply x2 (mains power grid, generator or inverter) |
B | Blue Smart IP22 Chargers x2 |
C | Fuses / circuit breakers x2 (locate as close as practical to DC positive busbar) |
D | DC positive and negative busbar |
E | Fuse / circuit breaker (locate as close as practical to battery) |
F | SmartShunt or BMV battery monitor shunt (SmartShunt/BMV is optional, locate as close as practical to battery) |
G | Temperature and voltage sensor (Optional accessory, PN: ASS000100000) |
H | Battery / battery bank |
Notice
A VE.Smart Network must be setup between all Blue Smart IP22 Chargers connected in parallel (and the optional SmartShunt or BMV battery monitor, if used) to enable Bluetooth connectivity and communication between devices; refer to the 'Advanced Configuration > VE.Smart Networking’ section for more information.