Setup using VictronConnect
The charge mode and charge current limit most appropriate for the battery type and capacity can also be selected using a Bluetooth enabled device (mobile phone or tablet) with the VictronConnect app.

For further information about the VictonConnect app refer to the VictronConnect manual.
To setup using Bluetooth:
Download and install the VictronConnect app onto the Bluetooth enabled device (mobile phone or tablet).
The VictronConnect app can be downloaded from the following locations:
Android - Google Play Store
iOS/Mac - Apple App Store
Windows and other - Victron Energy website > Downloads > Software
Enable Bluetooth on the Bluetooth enabled device (mobile phone or tablet) if not already enabled, but do not attempt to pair with the Blue Smart IP65 Charger.
Connect the Blue Smart IP65 Charger AC power cable to a mains power outlet; after a short delay the TEST LED will begin to blink, until the charger determines if the battery will successfully accept charge (for up to 2 minutes).
Open the VictronConnect app and locate the Blue Smart IP65 Charger in the Device list Local page, under Other devices.
In case the Blue Smart IP65 Charger does not automatically appear, ensure that the mobile phone or tablet has Bluetooth enabled and is within close range, then perform a manual scan for devices by selecting the Scan button (round orange button with circular arrow) in the bottom right corner.
Select the Blue Smart IP65 Charger from the Device list Local page, under Other devices.
VictronConnect will attempt to establish a Bluetooth connection with the Blue Smart IP65 Charger and display the connection progress in the Connecting pop-up dialog box.
When attempting to establish a Bluetooth connection with a new/unpaired device, the Bluetooth pairing request pop-up dialog box will appear after a short delay; enter the default PIN code stated on a label located on the back of the charger (or try 000000 if there is no default PIN code label), then select Pair.
Select the Settings icon (gear in the top right corner) to access the Settings page.
Select the most appropriate integrated charge mode (Normal, Normal + Recondition, High, High + Recondition or Li-ion) from the Charge preset menu.
Ensure that recondition stage is only enabled when required, as unnecessary or overuse will reduce battery life.
If the maximum rated charge current is excessive, enable low current mode (charge current limited to a significantly reduced level - varies per model, refer to the 'Technical specifications' section for more information). To enable (or disable) low current mode select the required option from the Charge current menu; when enabled the selected charge mode LED (NORMAL / HIGH / LI-ION) will blink.
All settings are stored and will not be lost when the charger is disconnected from mains power or the battery.
Notice
To ensure proper charging, battery longevity and safe operation it is important to select a charge mode appropriate for the battery type and capacity being charged; refer to the 'Operation > Charge modes' section and the battery manufacturers recommendations for more information.