Skip to main content

Blue Smart IP22 Charger

History screen

The HISTORY screen is a very powerful reference as it contains historical usage data over the charger’s lifetime and detailed statistics for the last 40 charge cycles (even if the charge cycle is only partially completed).

VictronConnect_-_History_screen_-_BSC_IP22.jpg

By selecting the full screen view the data is displayed in landscape view with significantly more days visible at the same time.

VictronConnect_-_History_screen__landscape_.jpg
Charge cycle statistics
  1. Cycle overview

    Expandable bar chart showing the time spent in each charge stage and the charge capacity provided (in Ah) during each charge stage

  2. Status

    Confirms if the charge cycle was successfully completed or if it was ended early/interrupted, including the reason/cause

  3. Elapsed

    The elapsed time of the recharge stages (Bulk and Absorption)

  4. Charge

    Total capacity provided during the recharge stages (Bulk and Absorption)

  5. Maintain

    Total capacity provided during the charge maintenance stages (Float, Storage and Recondition)

  6. Type

    The charge cycle mode used; either a ‘Built-in preset’ mode or a custom ‘User defined’ configuration

  7. Vstart

    Battery voltage when charging commences

  8. Vend

    Battery voltage when charging is complete (end of absorption stage)

  9. Error

    Displays if any errors occurred during the charge cycle, including the error number and description

Charger lifetime statistics
  1. Operation time

    The total operation time over the lifetime of the charger

  2. Charged Ah

    The total charge capacity (in Ah) provided over the lifetime of the charger

  3. Cycles started

    The total charge cycles started over the lifetime of the charger

  4. Cycles completed

    The total charge cycles completed over the lifetime of the charger

  5. Cycles completed %

    The percentage of charge cycles completed over the lifetime of the charger

  6. Number of power-ups

    The number of times the charger has been powered up over the lifetime of the charger

  7. Number of deep discharges

    The number of times the charger has recharged a deeply discharged battery over the lifetime of the charger